ABSTRACT
BACKGROUND CONTEXT
During spine surgery, motor evoked potentials (MEPs) are often utilized to monitor both spinal cord function and spinal nerve root or plexus function. While there are reports evaluating the impact of anesthesia on the reliability of MEPs to monitor spinal cord function, less is known about the impact of anesthetics on the ability of MEPs to monitor spinal nerve root and plexus function.
PURPOSE
To compare the baseline monitorability and amplitude of MEPs during cervical and lumbar procedures between two cohorts based on the maintenance anesthetic regimen: a total intravenous anesthesia (TIVA) versus a regimen balanced with volatile inhalational and intravenous agents.
STUDY DESIGN/SETTING
Baseline MEP data from a total of 16,559 cervical and 6,196 lumbar extradural spine procedures utilizing multimodality intraoperative neuromonitoring (IONM) including MEPs between January 2017 and March 2020 were obtained from a multi-institutional database. Two cohorts for each region of spine surgery were delineated based on the anesthetic regimen: a TIVA cohort and a Balanced anesthesia cohort.
PATIENT SAMPLE
Age 18 and older
OUTCOME MEASURES
Percent monitorability and amplitudes of baseline MEPs.
METHODS
The baseline monitorability of each muscle MEP was evaluated by the IONM team in real-time and recorded in the patient's electronic medical record. The relation between anesthetic regimen and baseline monitorability was estimated using mixed effects logistic regression, with distinct models for cervical and lumbar procedures. Subsets of cervical and lumbar procedures from each anesthesia cohort in which all MEPs were deemed monitorable were randomly selected and the average peak-to-trough amplitude of each muscle MEP was retrospectively measured. Mixed-effects linear regression models were estimated (one each for cervical and lumbar procedures) to assess possible differences in average amplitude associated with anesthesia regimen.
RESULTS
At the time of surgery, baseline MEPs were reported monitorable from all targeted muscles in 86.8% and 83.0% of cervical and lumbar procedures, respectively, for the TIVA cohort, but were reported monitorable in just 59.3% and 61.0% of cervical and lumbar procedures, respectively, in the Balanced cohort, yielding disparities of 27.5% and 22.0%, respectively. The model-adjusted monitorability disparity between cohorts for a given muscle MEP ranged from 0.2% -16.6% but was smallest for distal intrinsic hand and foot muscle MEPs (0.2%-1.1%) and was largest for proximal muscle MEPs (deltoid: 10.8%, biceps brachii: 8.8%, triceps: 13.0%, quadriceps: 16.6%, gastrocnemius: 7.8%, and tibialis anterior: 3.7%) where the monitorability was significantly decreased in the Balanced cohort relative to the TIVA cohort (P < 0.0001). Relative to the TIVA cohort, the model-adjusted amplitude of an MEP in the Balanced cohort was smaller for all muscles measured, ranging from 27.5%-78.0% smaller. Relative to the TIVA cohort, the model-adjusted amplitude of an MEP was significantly decreased (P <0.01) in the Balanced cohort for the most proximal muscles (Percent smaller: deltoid: 74.3%, biceps: 78.0%, triceps: 54.9.0%, quadriceps: 54.8%).
CONCLUSIONS
TIVA is the preferred anesthetic regimen for optimizing MEP monitoring during spine surgery. Inhalational agents significantly decrease...(More)